Как писал ранее начал мониторить работу хддешек с помощью smartctl, но вот беда, добравшись до очередного сервера, и запустив привычное smartctl -a /dev/имя устройства, получил следующую бяку:
# smartctl -a /dev/ad10
smartctl 5.40 2010-10-16 r3189 [FreeBSD 8.2-RELEASE amd64] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar Green (Adv. Format) family
Device Model: WDC WD15EARS-00Z5B1
Serial Number: WD-WMAVU3360943
Firmware Version: 80.00A80
User Capacity: 1 500 301 910 016 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Thu Jun 23 12:25:20 2011 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Disable
т.е.
SMART support is: Available — device has SMART capability. — смарт доступен для этого винта
SMART support is: Disable — но блин выключен)))
Включить его еще проще чем мониторить:
# smartctl -s on /dev/ad10
smartctl 5.40 2010-10-16 r3189 [FreeBSD 8.2-RELEASE amd64] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF ENABLE/DISABLE COMMANDS SECTION ===
SMART Enabled.
ну и далее привычное:
# smartctl -a /dev/ad10
smartctl 5.40 2010-10-16 r3189 [FreeBSD 8.2-RELEASE amd64] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Caviar Green (Adv. Format) family
Device Model: WDC WD15EARS-00Z5B1
Serial Number: WD-WMAVU3360943
Firmware Version: 80.00A80
User Capacity: 1 500 301 910 016 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Thu Jun 23 12:28:25 2011 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (31800) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 255) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x3031) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 100 253 051 Pre-fail Always - 0
3 Spin_Up_Time 0x0027 182 182 021 Pre-fail Always - 5858
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 137
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
9 Power_On_Hours 0x0032 093 093 000 Old_age Always - 5347
10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 136
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 131
193 Load_Cycle_Count 0x0032 140 140 000 Old_age Always - 181043
194 Temperature_Celsius 0x0022 108 106 000 Old_age Always - 42
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.